AXIAL FANS
   

AXIAL FAN nominal diameter 300 mm (PNEUMATIC)

Mobile axial fan with 300 mm nominal diameter for various ventilation work.

Earthing Required.

Oper. Pressure: 5 Bar

TECHNICAL SPECIFICATION:
Order No. ATEX Guideline 94/9 EC Nominal Diameter Length Max Operating Pressure Air Consumption Volume Flow (Unrestricted) Noise Level Weight
    mm mm bar m3/min m3/s dB(A) kg
8 1611 0300 II2GcIIBT6 300 350 5 0.45 0.57 85.7 13.0
8 1613 0300* II2GcIIBT6 300 380 5 0.45 0.57 85.7 14.5
(*with seperate exhaust connection om housing)
   
   
  AXIAL FAN nominal diameter 300 mm (PNEUMATIC)

Mobile axial fan with 300 mm nominal diameter for various ventilation work.

Earthing Required.

Oper. Pressure: 5 Bar

TECHNICAL SPECIFICATION:
Order No. Nominal Diameter Length Max Operating Pressure Air Consumption Volume Flow (Unrestricted) Noise Level Weight
  mm mm bar m3/min m3/s dB(A) kg
8 1601 0300 300 350 5 0.58 0.78 87 13.0
8 1602 0300 300 380 5 1.16 1.00 85 13.0
8 1603 0300* 300 370 5 0.58 0.78 85 14.0
(*with seperate exhaust connection om housing)
   
   
  AXIAL FAN nominal diameter 300 mm (PNEUMATIC)

Stationary axial fan with 300 mm nominal diameter for various ventilation work.

Earthing Required.

Oper. Pressure: 4 Bar

TECHNICAL SPECIFICATION:
Order No. Nominal Diameter Length Max Operating Pressure Air Consumption Volume Flow (Unrestricted) Noise Level Weight
  mm mm bar m3/min m3/s dB(A) kg
8 1501 0300 300 410 4 1.28 1.53 101 22.0
   
   
  AXIAL FAN nominal diameter 300 mm (PNEUMATIC)

Stationary axial fan with 300 mm nominal diameter for various ventilation work. Suitable for eg. tank aeration, cleaning work and many other applications in explosive areas.

Earthing Required.

Oper. Pressure: 4 Bar

TECHNICAL SPECIFICATION:
Order No. ATEX Guideline 94/9 EC Nominal Diameter Length Max Operating Pressure Air Consumption Volume Flow (Unrestricted) Noise Level Weight
    mm mm bar m3/min m3/s dB(A) kg
8 1531 0300 II2GcIIBT6 300 410 4 2.02 1.57 99.0 21.0
   
   
  AXIAL FAN nominal diameter 300 mm (ELECTRIC)

Electric fan, especially for explosive areas with 300 mm nominal diameter and protection class IP55.

Earthing Required.

Oper. Voltage: 110/230/400 V

TECHNICAL SPECIFICATION:
Order No. ATEX Guideline 94/9 EC Nominal Diameter Nominal Speed Motor Output Nominal Voltage Current Consumption at nom. voltage Alternating current single phase Alternating current three phase Volume Flow (Unrestricted) Noise Level Weight
    mm rpm kW V A Hz Hz m3/s dB(A) kg
8 1020 0140 II2GcIIBT3 300 2,840 0.35 230/400 1.6/0.92     1.0 86.0 20.0
8 1020 0840 II2GcIIBT3 300 2,900 0.37 110 5.1 50 50 1.0 85.0 20.5
8 1020 0850 II2GcIIBT3 300 2,900 0.37 110 5.1 50   1.0 85.0 20.5
8 1020 0860* II2GcIIBT3 300 2,900/3,480 0.37 110 5.1 50/60   1.0 85.0 20.5
8 1020 0870 II2GcIIBT3 300 2,870 0.37 230 2.3 50   1.0 85.0 20.5
(*incl ON/OFF switch)
   
   
  AXIAL FAN nominal diameter 400 mm (PNEUMATIC)

Built in fan with 400 mm nominal diameter and increased conveying volume.

Earthing Required.

Oper. Pressure: 4 Bar

TECHNICAL SPECIFICATION:
Order No. Nominal Diameter Length Max Operating Pressure Air Consumption Volume Flow (Unrestricted) Noise Level Weight
  mm mm bar m3/min m3/s dB(A) kg
8 1502 0300 400 420 4 2.11 2.70 92 32.0
   
   
  AXIAL FAN nominal diameter 400 mm (PNEUMATIC)

Built in fan with 400 mm nominal diameter and increased conveying volume for use in explosive areas.

Earthing Required.

Oper. Pressure: 4 Bar

TECHNICAL SPECIFICATION:
Order No. ATEX Guideline 94/9 EC Nominal Diameter Length Max Operating Pressure Air Consumption Volume Flow (Unrestricted) Noise Level Weight
    mm mm bar m3/min m3/s dB(A) kg
8 1532 0300 II2GcIIBT6 400 420 4 2.03 3.15 106 32.0
   
   
  AXIAL FAN nominal diameter 500 mm (PNEUMATIC)

Built in fan with 500 mm nominal diameter and increased conveying volume and a volume flow of more than 4 m3/s.

Earthing Required.

Oper. Pressure: 4 Bar

TECHNICAL SPECIFICATION:
Order No. Nominal Diameter Length Max Operating Pressure Air Consumption Volume Flow (Unrestricted) Noise Level Weight
  mm mm bar m3/min m3/s dB(A) kg
8 1503 0300 500 520 4 2.73 4.33 105 46.0
   
   
  AXIAL FAN nominal diameter 500 mm (PNEUMATIC)

Built in fan with 400 mm nominal diameter and increased conveying volume and a volume flow of more than 4 m3/s for use in explosive areas.

Earthing Required.

Oper. Pressure: 4 Bar

TECHNICAL SPECIFICATION:
Order No. ATEX Guideline 94/9 EC Nominal Diameter Length Max Operating Pressure Air Consumption Volume Flow (Unrestricted) Noise Level Weight
    mm mm bar m3/min m3/s dB(A) kg
8 1533 0300 II2GcIIBT6 500 520 4 2.73 4.33 105 46.0
   
   
  AXIAL FAN nominal diameter 600 mm (PNEUMATIC)

Our most powerful fan with a volume flow of more than 5 m3/s.

Earthing Required.

Oper. Pressure: 4 Bar

TECHNICAL SPECIFICATION:
Order No. Nominal Diameter Length Max Operating Pressure Air Consumption Volume Flow (Unrestricted) Noise Level Weight
  mm mm bar m3/min m3/s dB(A) kg
8 1504 0300 600 520 4 3.84 5.83 86 58.0
   
   
  AXIAL FAN nominal diameter 600 mm (PNEUMATIC)

Our most powerful fan with a volume flow of more than 5 m3/s for use in explosive areas.

Earthing Required.

Oper. Pressure: 4 Bar

TECHNICAL SPECIFICATION:
Order No. ATEX Guideline 94/9 EC Nominal Diameter Length Max Operating Pressure Air Consumption Volume Flow (Unrestricted) Noise Level Weight
    mm mm bar m3/min m3/s dB(A) kg
8 1534 0300 II2GcIIBT6 600 520 4 3.84 5.83 99 58.0