Due to the venturi principle, these robust pneumatic stainless steel fans are maintenance-free and free of wear and tear. The practical handle ensures mobile work at universal applications. Earthing required.
Technical Data
| ORDER NO. | 8 1642 0010 |
| ATEX Specification | IM2ExhIMbT6 |
| Energy source | Pneumatic |
| Operating pressure | 2-6 bar |
| Nominal diameter | 204.00 mm |
| Volume flow (unrestricted blowing) at 2 bar | 39.2 m³/min |
| Volume flow (unrestricted blowing) at 3 bar | 47.0 m³/min |
| Volume flow (unrestricted blowing) at 4 bar | 56.5 m³/min |
| Volume flow (unrestricted blowing) at 5 bar | 68.0 m³/min |
| Volume flow (unrestricted blowing) at 6 bar | 81.5 m³/min |
| Volume flow (unrestricted sucking) at 2 bar | 31.9 m³/min |
| Volume flow (unrestricted sucking) at 3 bar | 39.2 m³/min |
| Volume flow (unrestricted sucking) at 4 bar | 47.0 m³/min |
| Volume flow (unrestricted sucking) at 5 bar | 56.6 m³/min |
| Volume flow (unrestricted sucking) at 6 bar | 67.9 m³/min |
| Air consumption (at 2-6 bar) | 6.3-9.7 m³/min |
| Length | 450.00 mm |
| Material of housing | Stainless steel |
| Connection | G3/4″female |
| Noise level LpA | 115.8 dB(A) |
| Weight | 9.90 kg |
| Fields of application / branch | Energy and pipeline construction; Metal industry and steel construction; Mining; Plant and mechanical construction |